Manufacturer | AKSA Power |
Condition | Factory New with Industry Leading 2 Year / 2000 Hour Warranty |
Model | APD-ULJ150 |
KW | 150 |
EPA Emissions | TIER 3 |
Engine Model | John Deere Model 6068HF285 Rated HP: 237 @ 1800 RPM |
Fuel | Diesel |
RPM | 1800 |
Control System | Deep Sea Electronics DSE7320 |
Generator End Brand | Stamford 12 Lead (Standard) |
Voltage Options | 480/277, 208/120, 240/120, 600/347 & More |
Phase | 3 Phase |
Hertz | 60 Hz |
Enclosure |
Level One Sound Attenuated Enclosed |
Fuel Tank |
275 Gallon 24 Hour Base Tank / By Tramont |
Warranty |
STANDARD: 2 Year / 2000 Hours Included
OPTIONAL: 5 Year / 2000 Hours (Additional Cost)
|
Starting Voltage | 12 Volt, One Battery Included |
Radiator | Engine Driven, Unit Mounted |
Muffler |
STANDARD: Residential Grade Silencer OPTIONAL: Critical Grade Silencer (Additonal Cost) |
Main Circuit Breaker |
STANDARD: 480/277 Breaker Included OPTIONAL: Lower Voltages (Higher Amperage), Additional Functions (Additional Cost) |
Battery Charger |
STANDARD: 4 Amp Included OPTIONAL: 10 / 20 Amp (Additional Cost) |
Delivery Estimate |
12-14 Weeks |
Save thousands and buy NEW from Green Industrial today!
**Full Technical Specifications & FAQ's Below**
AKSA Power Model APD-ULJ150 Technical Specifications
STANDARD FEATURES & ACCESSORIES:
- UL2200 Listing
- 150 MPH Wind Rating
- Heavy Duty steel Base-Frame
- Anti-Vibration Pads
- Residential Grade Silencer Inside Enclosure
- Flex Fuel Lines
- Oil Drain Valve & Extension
- Emergency Stop Switch
- Battery, battery Rack & Cables
- Battery Charger (4 amp)
- Main Line Circuit Breaker (80 % Load Rated)
- Jacket Water Heater (500W)
- Operations Manual
- Standard 2 Year / 2000 Hours Limited Warranty
Digital : Yes
Model : DSE7320
DSE7320 is an advanced control system, suitable for a wide variety of single, diesel or gas, gen-set applications. Monitoring and an extensive number of engine parameters, the module displays warnings, shutdowns and engine status information on the back lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts (with external modem).
- UL Recognized, NFPA110 Level 1 Compatible
- LCD text display, key menu navigation and front panel editing
- Off/Manual/Auto model switch
- Two wire starting/stopping in Auto mode
- Engine exerciser
- IP65 front panel rating with supplied sealing gasket
- Configurable 9 inputs, 8 outputs with expansion capability
- Real time clock provides accurate event logging
- Fully configruable via ESE Configuration Suite PC software
- Remote SCADA monitoring and BMS integration features
- License free PC software
UNIT SPECIFIC INFORMATION FOR:
AKSA Model APD-ULJ150
KW RATING: 150
FUEL: Diesel
ENGINE INFORMATION
Manufacturer : John Deere
Engine Model : 6068HF285
Cylinders : 6
Configuration : In-Line
Max Power HP : 237
Aspiration : Turbo Charged & Air To Air Aftercooled
Total Displacement : 6.8 Liter (415 Cubic Inch)
Compression Ratio : 19:1
Governor Type : Electronic
Fuel Consumption Rates Standby:
(110% Load / 11.8 Gal/P/Hour)
(100% Load / 10.9 Gal/P/Hour)
(75% Load / 8.5 Gal/P/Hour)
(50% Load / 6.2 Gal/P/Hour)
Starting System Voltage : 12 Volt DC
Battery Quantity x rating & CCA : 1 Battery, 80ah, 622 Cold Cranking Amps
GENERATOR END INFORMATION
Manufacturer : Stamford
Model: UCI274F Winding Number 311 (or) UCI274F Winding #06 Dedicated For Single Phase
Design : 4 Pole, Drip Proof, Rotating Field
Leads : 12, (Or 4 Pole if Single Phase Dedicated)
Voltage Regulator : Solid State, Volts/Hz
Voltage Options Standby :
1. 480/277 (3 Phase, 0.8 PF, 60 Hz) (203 Amps)
2. 440/254 (3 Phase, 0.8 PF, 60 Hz) (221 Amps)
3. 240/139 (3 Phase, 0.8 PF, 60 Hz) (406 Amps)
4. 240/120 (3 Phase, 0.8 PF, 60 Hz) (406 Amps)
5. 208/120 (3 Phase, 0.8 PF, 60 Hz) (468 Amps)
6. 600/347 (3 Phase, 0.8 PF, 60 Hz) (180.4 Amps)
7. 240/120 (1 Phase, 1.0 PF, 60 Hz) (563 Amps)
Phase : 3 or Single
Hertz : 60
Stand by Rating : 150 KW
BASE MOUNTED FUEL TANK INCLUDED :
Tramont 24 Hour Base Tank (275 Gallons) (Additional Weight 1530 Lbs) (160"L x 43"W x 17"Tall)
UNIT MOUNTED CIRCUIT BREAKER OPTIONS: Yes (Comes Standard)
UNIT MOUNTED BATTERY CHARGER: Yes (Comes Standard)
UNIT MOUNTED ENGINE DRIVEN RADIATOR : Yes
BATTERIES INCLUDED: Yes
BASIC DIMENSIONS: 116 Inches Long x 43 Inches Wide x 54 Inches Tall (Open Skid, No Tank or Enclosure)
WEIGHT: 3650 Pounds (Open Skid, No Tank or Enclosure)
- Fuel Level Sensor
- 5 Gallon Spill container
- High Level Fuel Switch
- Remote Alarm Panel
- Dual Level Switches
- Overfill Prevention Valve
- Fuel Line Check Valve
- FDEP Listing
- Michigan DEQ Listing
- Michigan DEQ adder for tanks within code mandated distance from building
- 12 foot vent extension
- Bottom Channel adder for tanks
- John Deere
- Perkins
- Volvo
- Mitsubishi